Structure Fire
145 Holly, Grand Rapids
Timeline
- Engine 2 staging two units at 100 block of Holly, north side of the road west of Walden
- Smoke still coming from a vent on the Charlie (rear) side of the round silo; crews checking conditions
- Crews report heavy smoke still visible but cannot see down into the silo
- Crews conducting 360-degree walk-around inspection of the silo, checking the back (Charlie) side
- Command requesting additional crews to stage and stand by for the incident
- Command requesting crews to stage and stand by; tools to be brought down when needed
- Command reports water application is helping clear smoke from the exterior
- Command directing crews to remove roof vents; vent closest to the fire producing more smoke
- Crews removed one roof vent; working on the second vent to aid in ventilation and smoke removal
- Roof crew preparing to deploy hose line down through second vent opening for interior attack
- Roof crew advised to use caution when removing vents; metal rail support missing in that section due to the vent openings
- Command authorizing roof crew to remove one vent and apply water into the opening to attack the fire from above
- Smoke diminishing after water applied through roof vent opening
- Command checking whether smoke from first roof vent is staying down or coming back up after opening second vent
- Water showing progress; still some residual smoke from the first vent hole, not fully extinguished yet
- Smoke coming out of the lowest door on the front (Alpha side) of the building
- Command reports a hot spot on the wall about halfway down the silo, directly below the vents; crews directed to aim water straight down the wall at that location
- Crews directing water along a pipe angled from the hot spot on the silo wall to attack the fire from a new angle
- Crews adjusting nozzle aim to target the wall where the hot spot is located on the silo
- Crews spraying water directly at the wall where the hot spot is located on the silo
- Crews call for Star 3 unit to bring elevator equipment to assist at the scene
- Firefighter Tell breaking through walls with water stream; heat signature increasing, indicating hidden fire being opened up
- Thermal imaging still shows heat about halfway down the wall, but smoke is diminishing; firefighters are making progress
- Firefighter spraying the wall is hearing noise and experiencing increased heat rising toward his gloves; heat source still present
- Command directing crews to continue spraying operations on the wall with positive effect
- Star 3 all clear from the scene.
- Crews continuing to spray; smoke levels unchanged, photos and video sent to command
- Command advises hot spot remains below beds; crews breaking through crust to reach seat of fire, heat staying high despite increased spraying
- Crews had temporary loss of control of nozzle while suppressing fire
- Crew on scene reports 1800 pounds of air remaining in SCBA cylinder; staying out of IDLH, requesting additional personnel to continue operations or will manage from current position
- Command authorizes crew rotation; crew member with low air supply will exit, fresh crew members standing by to continue operations; command maintaining accountability at scene
- Command reports a MILO (mobile incident light/command vehicle) en route to assist at the fire ground
- Firefighter Tell heading down from the fire; crew remaining in position to continue operations
- Water escaping from multiple openings, including the chimney and auger opening on the alpha side; crews continuing to supply water to control the fire
- Firefighter staging on the front (Alpha) side awaiting next crew member to join for continued operations
- On Charlie side: only one firefighter at a time needed away from direct vent exposure to maintain safe air supply
- Command directing another firefighter to the Charlie side to relieve operations
- Command requesting personnel to retrieve 2 1/2-inch hose line from upper level via rope
- Firefighter 30 heading up the aerial ladder
- Firefighter descending the aerial ladder while lowering a 2.5-inch hose line
- Crews requesting water supply to establish water flow for fire attack
- Crews retracting equipment from the roof during fire attack operations
- Crews moving to the Charlie side (rear) of the building during fire attack operations
- Roof Ops reports fire extinguishment complete on the Charlie side of the building
Radio recording 8:12 · 42 transmissions
0:00-8:12