Structure Fire
1121 Lyon Street NE, Grand Rapids · Midtown
Timeline
- RadioGRFD responding to a structure fire at 1100 block of Lyon Street NE
- PoliceGRPD dispatched: Assist Citizen or Agency
- RadioHeavy smoke showing with flames visible inside the house; all residents evacuated
- RadioOne resident attempting to re-enter the burning house
- RadioFemale resident attempting to re-enter the house to retrieve animals
- RadioEngine 11 on scene at one-story home with smoke showing; Engine 11 assumes command and starting a 360 walk-around
- RadioIncident command requesting Rescue 1 to search the home for animals
- RadioCommand checking if Truck 7 and Truck 1 are ready to supply water
- RadioWater supply established at 80 PSI for firefighting operations
- RadioEngine 3 on scene at the one-story residential
- RadioBattalion 6 on scene, assuming command at the one-story residential fire on Lyon Street NE
- RadioFour dogs in the home; Truck 1 and Engine 11 firefighters beginning fire attack
- RadioEngine 15 reports Engine 78's clamp valve was shut; water pressure limited to 20 PSI, unable to increase flow to the attack line
- RadioFour dogs located in the basement
- RadioEngine 71 able to establish water supply to the fire line
- RadioWater supply stabilized at 80 PSI to fire line; initially had pressure problems around 25-30 PSI
- RadioEngine 72 adjusting water supply pressure down to 75 PSI per incident command request
- RadioEngine 72 reduced water supply to 70 PSI; water stream is breaking up, indicating potential pressure or supply line issues
- RadioEngine 72 reports water pressure is good on attack line 2.5
- RadioCrews stretching another hose line to Truck 3's position
- RadioEngine 72 reports water supply depleted; crews need to reposition or establish new supply line
- RadioEngine 72 experiencing cavitation in water pump; powering down to restart supply line
- RadioEngine 3 checking for occupants in the structure
- RadioCrews working on the first floor and basement of the structure
- RadioMain fire being knocked down
- RadioTruck 3 establishing command at the scene
- RadioEngine 3 requests permission from Rescue 1 to ventilate windows on the left (Bravo) side to assist with basement fire attack
- RadioEngine 3 requesting permission from Rescue 1 to open windows on the left (Bravo) side for basement ventilation
- RadioWindows audible breaking on the Charlie (rear) side of the structure
- RadioCommand requesting crews break windows on the Charlie (rear) side of the structure; Truck 3 asked if they can accomplish that task
- RadioLast crew member exiting the building
- RadioFire attack crews report good knockdown on the fire; checking for smoke in the attic
- RadioRescue 2 entering to overhaul and check the attic for remaining fire
- RadioMain fire on the first floor is knocked down; crews still checking the attic for remaining fire
- RadioCommand requesting another hose line for fire attack on the attic
- RadioCrews requesting another hose line in the main floor hallway; ventilation being coordinated
- RadioEngine 3 ready to advance a hose line to the Charlie (right) side of the structure
- RadioCommand coordinating Engine 3 and Engine 11 for fire attack operations
- RadioCrews going to the hydrant to assist with water supply operations
- RadioEngine 11 withdrawing from the line; Rescue 2 taking over the hose line operations
- RadioCommand confirms Engine 11 withdrawing; Rescue 2 now assigned to fire attack
- RadioEngine 15 leaving a hose line open for Engine 72 to connect and refill water supply
- RadioCommand: hydrant to remain dressed; crews will refill Engine 72 after pre-connect is complete, then disconnect. Additional personnel needed at Engine 72.
- RadioCommand to fire attack: the engine does not have that capability
- RadioFire attack crews need more slack on the yellow hose line on the right (Delta) side of the building
- RadioCommand acknowledges request for more slack on the yellow hose line on the Charlie side
- RadioEngine 9 clear of the scene
- RadioCommand directing crews to check ceiling and attic for fire extension
- RadioCrews found smoldering fire extension in the attic; blown-in insulation present, indicating a prolonged overhaul operation ahead
- RadioCrews evacuating building through windows; additional resources requested; continuing interior salvage and exterior water application.
- RadioCommand arranging to supply foam through the hose line for fire attack
- RadioRescue 1 clear of the scene
- RadioCommand asks about shutting down the yellow hose line temporarily during operations
- RadioCommand authorizing crews to open and bleed the yellow hose line temporarily during operations
- RadioCommand directing fire attack crew to proceed
- RadioFire involvement found in attic towards B side, mid-level in bedroom area; crews holding off removing more ceiling until water is applied below to prevent spread
- RadioCommand coordinating foam supply and interior salvage operations; crews to ventilate contents through windows while foam arrival imminent to assist with fire attack
- RadioRescue 1 will have water supply restored and foam delivered to assist with fire suppression
- RadioFire attack crews requesting another company to relieve all firefighter rehab positions
- RadioTruck 1 standing by to relieve firefighter rehabilitation positions as crews rotate out
- RadioCrews report a working fire with significant involvement
- RadioFire attack team (Rescue 1) calling command
- RadioFire attack team reports good progress on the fire
- Radio40 minutes on scene time
- RadioEngine 8 dispatched to 1100 block of Lyon Street NE
- RadioTruck 2 on scene; conditions appear serious
- RadioCommand asked if a staging location has been identified for relief companies
- RadioCommand clarifying relief crews will stage for crew rotation and relief operations at the fire scene
- RadioAdditional unit arriving on scene to assess what crews need for relief operations
- RadioRescue 2 reports power has been shut off at the building.
- RadioUnit en route, two minutes out from the scene
- RadioSmall fuel spill reported at the scene
- RadioEngine 8, Engine 12, and Truck 2 released from scene; staging on Fuller Avenue until apparatus can be cleared from the area
- RadioIncident commander coordinating backup crew positioning; confirming second hoseline deployment
- Radio360 check complete; heat signatures detected on the back of the building. Interior crew operating in offensive attack mode. Command accountability tracked at Car 1; staging positioned to the east.
- RadioSupply line connected; crews waiting on hydrant hookup to finish dressing and establish water supply
- RadioCommand requesting ventilation fan on scene
- RadioInterior fire attack crew ready to enter; waiting for ventilation coordination
- RadioFire attack crew ready for ventilation fan to begin interior operations
- RadioHydrant connection being dressed and positioned for water supply
- RadioCommand reassigning crews: two units currently on the platform being replaced with another unit, reassigned units moving to ventilation duties
- RadioCommand coordinating fire attack: deploying a second hose line to the front door
- RadioWater supply lines established and ready for fire attack
- RadioFire found in the burn room visible through a window
- RadioFire confirmed in the bedroom window
- RadioSafety officer reports window is open in the burn room
- RadioAll visible flames knocked down; ventilation window open in the burn room
- RadioCommand assigns Truck 3 to assist fire attack group inside with a pike pole for overhaul
- RadioAlpine Car 4 reports gas secured at the structure
- RadioSmoke clearing; crews doing overhaul work, minimal remaining fire
- RadioAlpine Car 4 and Engine 51 clear of scene, assignment complete
- RadioFire believed to be out; no extension found through the drywall
- RadioUnits clearing the scene and returning to station for decontamination
- RadioEngine 3 clear and returning to district for decontamination
- RadioTruck 3 clear; returning to station
- RadioLine command directing crew to position at front of house for final water application to ensure fire is fully extinguished (overhaul operations)
- RadioChief 3 clear
- RadioEngine 11 clear; out of service at the station
- RadioEngine 11 clear; unavailable for decontamination
- RadioTruck 1 clear; out of service for decontamination
- RadioCar 97 clear of the scene
- RadioAlpine Car 4 clear of the scene
- RadioEngine 11 clear and available for next assignment
- RadioScene turned over to police; incident command terminated, all fire units clear
- RadioIncident command terminated; all units cleared (2244)
Radio recording 14:30 · 112 transmissions
What was said on the public scanner radio about this call, in order. Download MP4
In the news
From neighbors
- Live GR Team Reporter
Scene photo of the working fire on Lyon St NE (via Grand Rapids Professional Firefighters Local 366)
- Live GR Team Reporter
Facebook posts with photos of the Lyon St NE structure fire, Oct 7 evening: Grand Rapids Professional Firefighters photo carousel (1100 block of Lyon St NE): facebook.com/GrandRapidsPro… | El Informador photo post (1100 block of Lyon St NE): facebook.com/elinformadorus…
- Live GR Team Reporter
Video from the scene of the house fire on Lyon St NE, Wednesday night (via 13 ON YOUR SIDE / WZZM, 17 sec). Source: wzzm13.com/video/news/local…
- Live GR Team Reporter
Video from the scene of the house fire (via Facebook, 1 min). GRFD knocked down the fire and rescued four dogs from the basement, including one crews resuscitated. No injuries reported. Source: facebook.com/reel/108060028…